Accumulator Unit Native Slider
A BOP accumulator unit stores hydraulic energy and supplies controls for the selected BOP stack and hydraulic valves. FKDQ electrical and FKQ pneumatic control configurations require matched capacity and interfaces. Request a factory or supplier price from China with the complete control and documentation scope.
| Category | Specification |
|---|---|
| Product Name | Accumulator Unit |
| Model Range | all published FKQ and FKDQ control-system table entries |
| Applicable Industries | Oil & Gas; Energy & Mining |
| Application | Well-control equipment and drilling systems |
| API Requirements | applicable API 16D and project BOP-control-system requirements |
| Configuration | Confirm selected model and approved drawing |
| Selection | BOP operating volumes, accumulator capacity, hydraulic pressure, pumps, panel type, power supply and response requirements |
| Documentation | Specify inspection and traceability requirements |
| Factory Supply Scope | Confirm equipment, accessories and spare parts |
| Manufacturer Inquiry | Provide the approved equipment configuration and technical requirements |
| Supplier Inquiry | Confirm configuration and commercial scope |
| Exporter Inquiry | Specify packing and destination |
| Price | Request a configuration-based quotation |
| Chinese Equipment | Confirm model-specific interfaces |
| China Sourcing | Compare the same technical and delivery scope |
| API certified Procurement | Verify certificate validity and applicable product scope |
| Packaging & Delivery | Confirm order-specific packing and delivery terms |
A BOP accumulator unit supplies stored hydraulic energy to operate designated preventers and hydraulic valves during drilling and workover operations. The package can include a remote control system, driller's panel, high-pressure manifold, pipe rack, enclosure and associated cables or pneumatic lines according to the selected design.
FKDQ identifies the listed electrical-control family and FKQ the pneumatic-control family. Determine accumulator capacity, usable fluid volume, required operating pressure, pump arrangement and response duties for the actual BOP stack. Cold-area heating, diverter sequencing, alarms and rig control integration must be specified in the supply scope.
PLC compatibility and hazardous-area or classification requirements need project-specific engineering and documentary evidence. ATEX, NORSOK, DNV, ABS and other named approvals must not be presented as automatic certifications. Request the applicable inspection, functional-test and control documentation for the offered unit.
Accumulator Unit selection requires BOP operating volumes, accumulator capacity, hydraulic pressure, pumps, panel type, power supply and response requirements. Review the complete configuration and the approved installation drawing before ordering. When comparing a Chinese accumulator unit manufacturer, supplier or exporter, ask the factory to identify equipment, accessories, inspection and spare parts included in the price. For procurement in China, specify applicable API 16D and project BOP-control-system requirements. Verify the validity and scope of documentation requested for API certified supply; a product name or reference standard is not proof of certification.
| Model | Number of controlled objects | Accumulator unit | Explosion-proof motor Power (Kw) | Pump system displacement | Rated operating pressure of the system (Mpa) | Maximum operating pressure of the system (Mpa) | |||
| Total volume (L) | Available liquid volume (L) | Installation mode | Triplex pump (mL/r) | Pneumatic pump (mL/stroke) | |||||
| FKDQ1920-13 | 13 | 80×24 | 960 | Side / Rear | 18.5×3 | 80×3 | 120×5 | 21 | 31.5 |
| FKDQ1600-14 | 14 | 80×20 | 800 | Side / Rear | 18.5×2 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1600-12 | 12 | 80×20 | 800 | Side / Rear | 18.5×2 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1600-10 | 10 | 80×20 | 800 | Side / Rear | 18.5×2 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1440-14 | 14 | 60×24 | 720 | Side / Rear | 18.5×2 | 80×2 | 120×4 | 21 | 31.5 |
| FKDQ1280-10 | 10 | 80×16 | 640 | Side / Rear | 18.5×2 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1280-9 | 9 | 80×16 | 640 | Side / Rear | 18.5×2 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1280-8 | 8 | 80×16 | 640 | Side / Rear | 18.5×2 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ1280-7 | 7 | 80×16 | 640 | Side / Rear | 18.5×2 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ1200-17 | 17 | 60×20 | 600 | Side / Rear | 18.5×2 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1200-9 | 9 | 60×20 | 600 | Side / Rear | 18.5×2 | 80×2 | 120×3 | 21 | 31.5 |
| FKDQ1200-8 | 8 | 60×20 | 600 | Side / Rear | 18.5×2 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ960-8 | 8 | 60×16 | 480 | Side / Rear | 18.5×2 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ960-7 | 7 | 60×16 | 480 | Side / Rear | 18.5×2 | 80×2 | 120×2 | 21 | 31.5 |
| FKDQ800-8 | 8 | 40×20 | 400 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 800-7 | 7 | 40×20 | 400 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 800-6 | 6 | 40×20 | 400 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ720-7 | 7 | 60×12 | 360 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 720-6 | 6 | 60×12 | 360 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 640-6 | 6 | 40×16 | 320 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 640-5 | 5 | 40×16 | 320 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 480-5 | 5 | 40×12 | 240 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ 480-4 | 4 | 40×12 | 240 | Side / Rear | 18.5 | 80 | 120 | 21 | 31.5 |
| FKDQ320-5 | 5 | 40×8 | 160 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ320-4 | 4 | 40×8 | 160 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ320-3 | 3 | 40×8 | 160 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ240-3 | 3 | 40×6 | 120 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ200-4 | 4 | 25×8 | 100 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ160-3 | 3 | 40×4 | 80 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ150-2 | 2 | 50×3 | 75 | Side / Rear | 15 | 60 | 120 | 21 | 31.5 |
| FKDQ125-3 | 3 | 25×5 | 62.5 | Side / Rear | 7.5/11 | 28 | × | 21 | 21 |
| FKDQ80-3 | 3 | 40×2 | 40 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ80-2 | 2 | 40×2 | 40 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ75-2 | 2 | 25×3 | 62.5 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ63-2 | 2 | 63×1 | 31.5 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ50-2 | 2 | 25×2 | 25 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ40-2 | 2 | 40×1 | 20 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ25-2 | 2 | 25×2 | 12.5 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
| FKDQ25-1 | 1 | 25×2 | 12.5 | Side / Rear | 7.5 | 28 | × | 21 | 21 |
Confirm usable capacity and required response duty for the actual stack. Classification and hazardous-area approvals apply only when specifically documented for the offered package.




Accumulator Unit selection requires BOP operating volumes, accumulator capacity, hydraulic pressure, pumps, panel type, power supply and response requirements. Review the complete configuration and the approved installation drawing before ordering. When comparing a Chinese accumulator unit manufacturer, supplier or exporter, ask the factory to identify equipment, accessories, inspection and spare parts included in the price. For procurement in China, specify applicable API 16D and project BOP-control-system requirements. Verify the validity and scope of documentation requested for API certified supply; a product name or reference standard is not proof of certification.